347 - Evaluation of Single-Timepoint 177 Lu-PSMA-617 Dosimetry Platforms for Tumors and Organs at Risk

03:55pm - 04:05pm ET
Room 156

Presenter(s)

Srikrishna Tirumalareddy, BS Headshot
Srikrishna Tirumalareddy, BS - Thomas Jefferson University, Philadelphia, PA

S. Tirumalareddy1, S. Majid2, N. Haldar1, F. Adejolu1, K. Zarrabi3, E. Gingold4, J. W. DiNome1, F. Mourtada1, and L. J. Wilson1; 1Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, PA, 2Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA, 3Department of Medical Oncology, Thomas Jefferson University Hospital, Philadelphia, PA, 4Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA

Purpose/Objective(s):

Lutetium-based radiopharmaceuticals are emerging as a transformative approach to treating metastatic cancer. However, lack of standardization in single-timepoint (STP) dosimetry workflows may limit multi-institutional collaboration and impede shared clinical insight. This study aimed to evaluate STP dose variability across 4 platforms in 177Lu-PSMA-617 patients.

Materials/Methods:

Patients received up to six 7.4 GBq cycles of 177Lu-PSMA-617, with quantitative SPECT imaging acquired 72 hours post-cycle for up to 3 cycles. Volumes of interest (VOIs) included tumors, manually contoured and reviewed by a radiation oncologist, and the kidneys and parotids, auto-contoured with a validated tool (ProtegeAI, MIM). We performed STP dose calculations in 4 platforms: a MIRD-based organ-level approach (MIRD; MIRDcalc), a commercial Voxel S-Value system (VSV-C; MIM SurePlan MRT), a commercial Monte Carlo model (MC; Voximetry Torch), and an open-source Voxel S-Value tool (VSV-O; OpenDose3D). Madsen time integration was used in all platforms, except for VSV-C, which used the Hanscheid method. We evaluated tumor dosimetry in the 5 largest tumors per patient to focus on dominant lesions. Repeated Measures ANOVA with Bonferroni-corrected post hoc t-tests assessed differences between platforms (a = 0.05). Linear Mixed-Effects Models (LMEs) tested inter-patient and inter-platform variability, quantified by standard deviations (SDs).

Results:

We calculated kidney and parotid absorbed doses for 36 cycles over 27 patients, and 53 tumors across 10 patients over 13 cycles. Mean MIRD doses ± SDs (Gy) were 2.0 ± 0.7, 1.7 ± 1.1, and 9.9 ± 11.2 for kidneys, parotids, and tumors respectively. Doses significantly differed across platforms in all VOIs (ANOVA p = 2E-8). Bonferroni-corrected post hoc tests yielded significant differences in kidney doses between all platforms (p = 0.01). Parotid doses significantly differed across all platforms (p = 0.02), except for VSV-C, which did not differ from MIRD or VSV-O. For tumor doses, VSV-O differed from VSV-C and MIRD (p = 0.03), and MIRD differed from MC (p=0.04). All other comparisons were not significant. LME inter-patient SDs (Gy) were 0.7, 1.1, and 5.5, while inter-platform SDs were 0.1, <0.1, and 0.6, for kidneys, parotids, and tumors respectively.

Conclusion:

We evaluated STP kidney, parotid, and tumor doses following 177Lu-PSMA-617 in 4 platforms and found statistically significant differences between platforms in all VOIs, but SDs were small, suggesting limited clinical relevance. Furthermore, inter-patient variability dominated inter-platform variability in all VOIs. Tumor doses showed the greatest variability across patients, underscoring the need for personalized activity administration. Small inter-platform variability supports STP dosimetry as a reliable approach and encourages shared clinical insight, improving patient care.